10.2.2 ThruScan sX/sX-WP/s15-i/sX-i SRC-SCADA Remote Control Program
U s e r M a n u a l
Please enter your Registration Code for the activation of your SRC-SCADA Remote Control
Programmer. You can have your Registration Code from your dealer by e-mail or telephone.
1.1- Language - Select your language from “Setting” window.(English, German, Spanish, Turkish)
1.2- Connection – To work with a metal detector you need to connect it to a serial port via the cable. To make the
program, please make sure what port you are using, select the "Com Port" and choose COM1 to COM4. If the
communication is performed by Telephone Lines then the com-port of the modem should be
selected visually. You can check several ports simultaneously for the right communication.
1.3- If the communication would be done by telephone lines; then the phone number should be entered to “sX
Phone Number” window and pressed “Dial”. There is no difference between local (in house), domestic or
international communications.
1.4- Selection Of GATE NO - You have to give index number for each walk-thru from 1 to 99.
(Note: All ThruScan s number-1 at the factory out-put)
(Note: When you communicate with selected ThruScan
s
, you should disconnect the other Magnetic Walk-Thru
Metal Detectors from your network ! )
To change the ThruScan s index number: (Only one ThruScan
has to be connected to the network)
a) Arrange the communication. (Select right COM port)
b) Press “STOP” button,
c) Write “NEW”(Caps Letters!) to “IN COUNT” window,
d) Write the index number(1-99) you want to assign to that walk-thru to “OUT COUNT” window,
e) Pres toIN COUNT” button,
You can repeat this process with the other Magnetic Walk-Thru Metal Detectors under communication to assign
your own index number.
1.5- Select the ThruScan number from “GATE NO” window. This will up-date the complete information on your SCADA
screen at your pc for the data of the selected walk-thru.
STATUS” window will display not only your executions such as, RUN(X), STOP, READ ERROR, IR(INFRARED)
ERROR, LOW BATTERY etc.. i.e. the error codes (Telephone line disconnection displayed as READ ERROR) but also
the walk-thru’ errors are displayed.
1.6- In “Level Select” window; 20 security levels are existing of which NC (NILECJ) can not be changed. The other 19
can be assigned to the desired sensitivity. Last channel AD (AUTO DESIGNATE) is assigned for the automatic
designation of the metal volume. (Pls. refer to your “Manual” for further information)
You can change several Security Levels simultaneously and send together to your Magnetic Walk-Thru Metal
Detector. Please note that; The sensitivity assignments performed at “Sensitivity Select” are for ALL ZONES !
To change the Security Level Adjustments:
d) PressSTOP” button,
e) Select the Security Level you want to change its sensitivity,
f) Set it at a value between 0-245 ( 0- the most sensitive , 245- the less sensitive)
g) Send” it or them to your ThruScan. (One or more can be send at the same time ! )
1.7- By “Zone Select” section window; all zones can be adjusted separately.
1.8- ?” signs for all windows are for “HELP” menu to ease you to use SRC-Scada Remote Control Program.
1.9- “SEND” button resets old data and memorize the new assigned data to your ThruScan.
1.10- “Refresh” button reports the data of your ThruScan in every 30 secs to your PC. You could get data instantly
every second by pressing “Refresh” button. “Send” is not possible in Refresh Mode.
1.11- “Factory Settings” button enables to return to default settings. These settings can be re memorized by “SEND
button. Counter values do not change at this process.
1.12- Select “Real Time” from the “Options” at the bottom of the SCADA screen in order to observe the detection,
counting, audible, visible alerts instantly.
Select from “Options”(1 to 5) to set the alarms duration on the screen.
1.13- Select “Data Registration” from “Options” to register the history of incoming/outgoing and alarmed counter
values at an automatically opened file.
1.14- X” button is to exit from your SRC-SCADA Remote Control Programmer. This will shut down the
communication/telephone line also.