Elektral ThruScan Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Pomiary, testowanie i kontrola Elektral ThruScan. Elektral ThruScan User`s manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 57
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
WTMD
U
U
s
s
e
e
r
r
s
s
M
M
a
a
n
n
u
u
a
a
l
l
www.elektral.com.tr
MAIN CONTACT-FACTORY:
Ataturk Industrial Zone
M.K. Ataturk Blv. 23 Cigli
35620 Izmir -TURKEY
Phones : +90(0)232 376 7300
Fax : +90(0)232 376 7030
Release:12.03
Przeglądanie stron 0
1 2 3 4 5 6 ... 56 57

Podsumowanie treści

Strona 1 -

WTMD UUsseerr’’ss MMaannuuaall www.elektral.com.tr MAIN CONTACT-FACTORY:Atat

Strona 2

91.1 ThruScan s3  International Norms (NILECJ-0601.00 L1-3 / IP20/TS EN 60950-1, in accordance with CE and and produced under ISO 9001: 2008 QMS

Strona 3

10 1.2 ThruScan s6  International norms (NILECJ-0601.00 L1-3/IP20/EN60950-1) in accordance with CE and produced under ISO 9001: 2008 QMS  Mult

Strona 4

11 1.3 ThruScan s9 ThruScan s9 was chosen, “The Best Deal” in Dubai Safety Exhibition-2001, with the norms it provides, its specifications, perf

Strona 5

121.4 ThruScan sX ThruScan sX was introduced as “The Breaking News” at Abu Dhabi –Middle East Security & Safety Exhibition-2003 with its inn

Strona 6 - RISK OF ELECTRIC SHOCK

131.5 ThruScan sX-WP  International Norms (NILECJ-0601.00 L1-5 / IP55/ TS EN 60950-1) in accordance with CE and produced under ISO 9001: 2008

Strona 7

141.6 ThruScan s15-i  International Norms (NILECJ-0601.00 L1-5/ IP44/TS EN 60950-1), ECAC.CEAC DOC 30 Compliance, in accordance with CE and produ

Strona 8

151.7 ThruScan sX–i  International Norms (NILECJ-0601.00 L1-5/ IP44/TS EN 60950-1), ECAC.CEAC DOC 30 Standard 2 Compliance, in accordance with CE

Strona 9 - PIN CODE. See Section 6.8

162 INSTALLATION 2.1 TRANSPORTATION AND SITE SELECTION ThruScan WTMDs are being packed and shipped in two separate boxes “Control Unit” an

Strona 10

172.2.2 Arrange the major components as shown. 2.2.3 Lay the main Control Unit (with the control panel facing down) onto a soft, scratch free surfac

Strona 11 - 1.2 ThruScan s6

183. CONTROL (DISPLAY) PANEL & INDICATION INFORMATION The control panel functions are protected from unauthorized tampering by a l

Strona 12 - NOTE: You may reach

1 Contents Page PRAFACE ...

Strona 13 - ThruScan sX

19 3.1.4 UPS INDICATOR When the Mains Voltage is cut off the WTMD will continuously operate from the Battery, the battery mode operation indicati

Strona 14 - ThruScan sX-WP

203.3 TRAFFIC LIGHTS Location of the Traffic lights may vary as per different models. At the entrance part of the Two Side Panels (ThruScan s9), at

Strona 15 - ThruScan s15-i

213.6 RELAY CONTACT OUTPUTS (RJ11/12) Relay contacts (for phone connector) are present on ThruScan (on the side panel or on the control unit).

Strona 16 - ThruScan sX–i

22 4.1 PROGRAM MENU To enter the program MENU press the SEL(√) button once. The LCD display will change to show: “ENTER PASSWORD” with

Strona 17 - ThruScan

23 The preset security levels are designed to cover most eventualities for easy programming of your WTMDs. (S

Strona 18

24SECURITY LEVEL INDIVIDUAL ZONE SENS LEVEL [03] ZONE=[01]=020 NOTE: The sensitivity setting on security level NC is fixed according to NILECJ – Leve

Strona 19 - ThruScan, s

251-Press SEL(√) button when displayed as on the right. 2- To make an automatic assignment, according to the statement displayed; Pass the objecte

Strona 20 - sX/ s15-i/sX-i)

264.1.5 ALARM COUNTER 4.1.5.1 FOR; ThruScan s3/s6/s9/sX/sX–WP ThruScan have an internal alarm counter and its memory which will indicate the num

Strona 21

272. See Counts that are displayed, 3. To reset counts press SEL, and return to MENU, 4. Choose Y(yes) or N(no) by UP&DOWN buttons, 5. Press S

Strona 22

28NOTE: When reset to Factory defaults, this does not change the in & out counters. Only such displays as the sensitivity adjustments, programs o

Strona 23

2 Contents Page 4.1.1 Security Level & S

Strona 24

29UP&DOWN buttons – Then press SEL(√). 4. Select the 2nd digit of the password code by using the UP&DOWN buttons–Then press SEL(√). 5. Sele

Strona 25

30 4.1.13 ALARM TONE DURATION SELECT (*only for ThruScan sX/ sX-WP /s15-i/sX-i ) You may adjust the alarming tone period. T

Strona 26

314.1.16 ALARM RATE (*ThruScan s15-i/sX-i only) This menu is to Display the Percentage of Alarms generated by ThruScan s15-i/sX-i. Percentage of

Strona 27

32  ThruScan is always operating properly,  Program and sensitivity settings are correctly made,  LED VU display shows minimal interference(e

Strona 28

33 If an alarm sounds after the person re-enter the walk-through, he/she must be rescanned with a hand-held metal detector-HHMD and the cause of acti

Strona 29

34Error 06: Right Centre Zone - High Metal Detection for a prolonged period. Error 07: Left Bottom Zone - High Metal Detection for a prolonged period

Strona 30

35(* for ThruScan s3/s6/s9 mechanical lock is optional but the protection by 4 digit pin-code is the same.) 6.9 REGULATORY INFORMATION ThruSca

Strona 31

36Synchronization can also be done by using the Synchronization Cable. For this the Synchronization Cable (optional) must be used. If the cable con

Strona 32

376.19 WEIGHT (~ kgs.) ThruScan s3/s6/s9 ThruScan sX/s15-i/sX-i Main control & display unit : 7.9 Main control & display uni

Strona 33

38 Up to 99 ThruScan sX/sX-WP/s15-i/sX-i units can be controlled using the same cable with this type of connection. The hardware necessary for this r

Strona 34

3 Contents Page 7. OPTIONS ...

Strona 35

39 7.1.2 REMOTE CONTROL (by MODEM) The second accessory of the Remote Control Package is a specially modified modem. This modem is not a standar

Strona 36

407.2.2 SIDE PANEL PROTECTION COVER The “protection cover” is designed to protect the side panels from drizzled rain. It is made of plastic mat

Strona 37

41 WARNING: If ‘Remote Control’ warning is displayed on LCD when entered the code, then the PIN code of the ThruScan is set to [8888]. The PIN Code m

Strona 38 - and you may send the

424 External trigger for capture 4.1 Activation depends on which camera is active. 4.2 If ch1 is in view, if TG1 active, capture a photo from ch1, if

Strona 39 - SECRETLY!...(optional)

437.4.6 Set up frame rate setting, use ( OK ) to select 1, 2, 5, 10,15fps 7.4.7 Set up recording duration, press (CH +/ CH -) to select 5, 10, 20, 30

Strona 40

44REMOTE CONTROL BUTTONS : Is used for to exit from IR control menu. Or to go back to main menu in IR control menu. V + : RIGHT V - : LEFT CH

Strona 41

45 7.11 Queue Barrier Chrome plated, 90 cm height, weights approx. 9 kg, 2.5 m length and 48 mm thick red ribbon with yellow ThruScan logo print. 7

Strona 42 - Operation

468.2. REPAIR The modular design of ThruScan facilitates mounting, dismounting and maintenance. It is easy to follow procedures with its user-frien

Strona 43

47 9 TROUBLE SHOOTING You may find the answers to your basic questions related with the mounting and operation of y

Strona 44

482121You should mount your WTMD as in the necessary distance, away from moving metal objects. This distance should at least be 1 meter depending on

Strona 45

4 PREFACE Dear User; You have taken some serious measures for the security of the Entrance-Control of necessary environments with the Magne

Strona 46

49 * I want to operate my WTMD through a standard telephone line using the Remote Control SRC-SCADASoftware. How should I make the connection? You

Strona 47

50* What is the maximum distance could be between my computer and ThruScan ? It depends on the Cu-quality/Thinnet of the cable. With the cable suppl

Strona 48

51Your WTMD has a separate relay outputs and Modem/RS232 output for PC. You may monitor the cases of alarm from a distance. For details See Section 3

Strona 49 - BUS NETWORK

5210.2.1 ThruScan s3/ s6/s9 SRC-SCADA Remote Control Program User Manual Please enter your Registration Code for the activation of your SRC-SC

Strona 50

5310.2.2 ThruScan sX/sX-WP/s15-i/sX-i SRC-SCADA Remote Control Program

Strona 51

5410.3 IRDA REMOTE CONTROL UNIT MANUEL Pin Code Insertion: It is necessary to insert 4 digit pin-code (****) to start procedures. Thus first 4 di

Strona 52

5510.4 User’s manual for Wheeled Transportation Accessory /WTMD Wheeler Operation: This device is designed as an accessory for the WTMD Models(al

Strona 53 - s3/s6/s9

56Seal/Signature 10.5 CERTIFICATE OF WARRANTY FULL WARRANTY CERTIFICATE Your Unit, Model:...

Strona 54

5 C O N T E N T S Procedures and Safety Warnings before using ThruScan Technical specifications of ThruScan Preparations Mounting

Strona 55

6Necessary Procedures and Safety Warnings Prior to Using ThruScan Avoid direct light from entering to the infrared sensors apertures (see Sec. 6.

Strona 56

7CAUTION! Misuse of this equipment specified by the manufacturer may result in damage to property or injury to persons. Technical Specifications

Strona 57

81. GENERAL DESCRIPTION ThruScan s3/s6/s9/sX/s-15i/sX-i/sX-WP WTMD’s all are simple to operate and with advanced microprocessor controlled, dig