If an alarm sounds after the person re-enter the walk-through, he/she must be rescanned with a
hand-held metal detector-HHMD and the cause of activation should be determined. One should also
remember a metal possibility by prosthesis organs.. i.e. pacemakers, etc.
The zone lights facilitate the screening process by indicating the location of all
causes of alarm
activation within 9 zone areas. In cases where there is more than one object, the lights appear in
each array that requires investigation. This enables the operator to know from which area(s)
objects require removal and to concentrate on the problem areas when hand scanning, resulting in
improved overall security and increased transition.
If the operator finds a weapon or another forbidden object, he or she should follow the
in-house screening procedures and the supervisor’s instructions regarding the appropriate
response.
NOTE: Remember that the cause of every alarm MUST be determined. If in doubt the
operator should consult their authorized personnel or manager
.
6 TECHNICAL SPECIFICATIONS
6.1 ELECTRONICS
Digital-controlled, pulse induction, multi-zone metal detector; target location is discernible on the
left and right sides of the body, from head to toe in 9 distinct zones. (Both the detection and
control circuitries comprise microprocessors.) Modular-designed electronics facilitate mounting and
maintenance easily.
6.2 DETECTION FIELD
ThruScan’s multi-zone detection field provides and completes horizontal and vertical uniformity.
The sensitivity of each field can be adjusted to meet the requirements of specific security
applications
(*only for
sX/ sX-WP /s15-i/sX-i
).
ThruScan’s unique design enables the
operator to identify targets within 9 zones. Detection is precise, regardless of a target’s location or
orientation within the archway.
6.3 LANGUAGE
English & German & Turkish & Spanish is standard. (other languages optional)
6.4 SELF-TEST
As soon as your ThruScan is turned on, a self-test routine occurs for about 10 seconds during
which time the warning buzzer will sound to warn that the unit is not yet ready for use. Should a
fault in the system be detected a fault code will be displayed upon the LCD display.
Failure Codes are as follows:
Error 00: The walk through infrared detector is blocked or failed.
Error 01: Left Top Zone - High Metal Detection for a prolonged period.
Error 03: Right Top Zone - High Metal Detection for a prolonged period.
Error 04: Left Centre Zone - High Metal Detection for a prolonged period.