36
Synchronization can also be done by using the Synchronization Cable. For this the Synchronization
Cable (optional) must be used.
If the cable connection is maintained, one of the WTMD operates as the main (master) unit and
the other as the slave (satellite).
For the synchronization of the units:
1- Attach the connection cable to the sockets with the
sticker on the side panels.
2- Choose the main and slave unit
3- Open the back cover of the control panel of the slave
4- Turn OFF the switch on the main card on the control panel of the slave
5- Close the back cover of the control panel of slave.
The WTMDs will operate by pressing ON after these steps taken.
NOTE: When the main WTMD is OFF the slave can not operate
NOTE: If the WTMDs will be used separately again then plug out the synchronisation
cable (phone cable connections-RJ 11/12) from the side panels. Then switch the key of
the slave unit from OFF to ON position.
NOTE: During synchronisation procedures, the WTMDs’ should be Shut OFF.
6.14 ELECTRICAL REQUIREMENTS
Operating voltage: 70 – 270 VAC (supply should be well grounded/earthed and the ground must
be in proper electrical NORMs) - 50/60 Hz.
*External SMPS (Input:100-240 vac, 50/60Hz, 1.0 A Output: 15 vdc, 2.66 A)
(*only ThruScan sX WP)
Power consumption: 10 Watts in standby mode
20 Watts in alarm mode (max)
6.15 CONSUMPTION EFFICIENCY
As described in article nr. 6.14 above, electrical values can be found. WTMDs are being produced to
operate 7/24.
However, for energy saving the WTMD is in Stand By mode when there are no passers by.
6.16 OPERATING TEMPERATURES
(-4º F) -20º C to +(158º F) +70º C
6.17 HUMIDITY
Up to 95% non-condensing.
6.18 THROUGHPUT/TRAFFIC RATE
High speed detection circuitry enable a very high transition of around 240 persons/minute but due
to alarms this accepted and approximated to 60~65 persons per minute (may vary with the metal
magnitude).