25
1-Press SEL(√) button when displayed as on the right.
2- To make an automatic assignment, according to the statement
displayed; Pass the objected metal through the WTMD with a person
without any other metal object, when the traffic-light is green,
3- Repeat the procedure in
# 2 -3/2,
4- Repeat the procedure in
# 2-3/3,
5- Thus the WTMD determines the approximate size of the metal that
you’ve passed 3 times and inquires whether you want a general or
zone assignment,
6- If the general assignment is being selected, the unit repeats
procedure 4.1.1 itself.
7- Select the zone and assign by repeating the procedure 4.1.1.
NOTE: Make sure there are no moving metals near the WTMD
and make sure that there are not any moving metals or
passing any metal through the WTMD also avoid touching, shaking the panels, while
the sensitivity assignment procedures.
NOTE: You cannot return to normal operating mode unless the whole assignment
procedure is completed at the self Designation AD) MENU completely,.
4.1.4 ALARM VOLUME & TONE ADJUSTMENT
ThruScan has 10 separate alarm volume levels, in 10 different tones from 1(quietest) to
10(loudest) as well as 00, which disables the audible alarm tone (but not the visual indication).
The Factory default alarm volume setting is = 05
The Factory default tone setting is = 09
The alarm volume can be set as follows:
1. Press UP&DOWN buttons from the MENU until the ALARM
VOLUME sub-MENU option is displayed,
2. Current Alarm Volume will be displayed, (i.e. 05 displayed),
3. Use UP&DOWN buttons to reach the required volume setting,
4. To fix the alarm volume press the SEL(√) button then “TONE” will be automatically
displayed,
5. Use UP&DOWN buttons to reach the required tone type,
6. Press SEL(√) button to select and fix the setting.
Press UP&DOWN buttons to move to the next sub-MENU option or press RUN(X) button to store
the changes and thus return to the normal operating mode.
USED FOR AUTO
DESIGNATE OF
SECURITY LEVEL TO
CONTINUE PRESS SEL
WHEN TRAFFIC LED IS
GREEN, ENTER
METAL OBJECT THEN
PRESS SEL(√) 3/1
WHEN TRAFFIC LED IS
GREEN, ENTER
METAL OBJECT THEN
PRESS SEL(√) 3/2
WHEN TRAFFIC LED IS
GREEN, ENTER
METAL OBJECT THEN
PRESS SEL(√) 3/3
DESIGNATE-DETECTMODE
ALL ZONES 00 ZONE 01
[00]
AUTO DESIGNATE MODE
TO DESIGNATEPRESSSEL
LEVEL [AD]=000
AUTO DESIGNATE MODE
TO DESIGNATEPRESSSEL
ZONE=[02]=000
ALARM VOL. AND TONE
VOLUME = [05]