UP&DOWN buttons – Then press SEL().
4. Select the 2nd digit of the password code by using the UP&DOWN buttons–Then press
SEL().
5. Select the 3rd digit of the password code by using the UP&DOWN buttons–Then press
SEL().
6. Select the 4th digit of the password code by using the UP&DOWN buttons–Then press
SEL().
Press
UP&DOWN buttons and change to the next sub-MENU option or press RUN(X) button to
store the changes and thus return to the normal operating mode.
4.1.11 ENVIRONMENT NOISE LEVEL
This MENU is prepared to measure the electromagnetic noise level of
surrounding and thus help the user to select the sensitivity level
accordingly.
1- Press UP&DOWN buttons until the ENVIRONMENT NOISE
LEVEL sub-MENU option is displayed.
2- Enter the MENU by pressing SEL() button,
3- The noise value of the environment will be displayed,
4- Return to MENU by pressing RUN(X).
NOTE: People carrying metal objects must not pass through or near the WTMD while
carrying out this process.
A higher value than the threshold noise level should be selected for sensitivity level to
avoid false alarms depending the users experience and instinct.
4.1.12 PASS SENSOR
(
*for only
ThruScan
sX/ sX-WP /s15-i/sX-i )
ThruScan operates to detect only the passing metal metals through archway. With this extra
feature it is possible to delete this function.
To realize this;
1- Find “PASS SNSR” sub-MENU by UP&DOWN buttons,
2- Enter the MENU by pressing SEL() button,
3- Select your alternatife by UP&DOWN buttons as;
* N (no) To shut PASS SNSR.(passing is not necessary for
detection) or vice versa.
4- Return to MENU by pressing RUN(X).
Press UP&DOWN buttons and change to the next sub-MENU option or press RUN(X) button to
store the changes and thus return to the normal operating mode.
ENVIRONMENT NOISE
LEVEL
ENVIRONMENT NOISE
LEVEL
NOISE = 000
PASS SNSR
Y<==>N
PASS SNSR
Y<==>N
ACTIVE = Y